Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.723
Filtrar
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 80-84, 2024 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-38384222

RESUMO

Through the effective application of Essential Principles of Safety and Performance of Medical Devices and IVD Medical Devices (EP), to continuously improve the corresponding management tools to ensure the safety and effectiveness of medical device in the quality management system, risk management system, evaluation of safety and effectiveness for the supervision departments and manufacturers. The current status of the application of EP and the application issues are analyzed in the study. Take artificial joint products for example, the idea of using EP in quality management system, risk management system and evaluation of safety and effectiveness is investigated, and several thoughts are proposed. Supervision departments should strengthen the unified understanding of EP, develop requirements according to the classification of medical device,and refine specific execution requirements.


Assuntos
Equipamentos e Provisões , Gestão de Riscos , Equipamentos e Provisões/normas
2.
Int J Technol Assess Health Care ; 40(1): e2, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38179661

RESUMO

OBJECTIVES: Lack of evidence regarding safety and effectiveness at market entry is driving the need to consider adopting a lifecycle approach to evaluating medical devices, but it is unclear what lifecycle evaluation means. This research sought to explore the tacit meanings of "lifecycle" and "lifecycle evaluation" as embodied within evaluation models/frameworks used for medical devices. METHODS: Drawing on qualitative evidence synthesis methods and using an inductive approach, novel methods were developed to identify, appraise, analyze, and synthesize lifecycle evaluation models used for medical devices. Data was extracted (including purpose; audience; characterization; outputs; timing; and type of model) from key texts for coding, categorization, and comparison, exploring embodied meaning across four broad perspectives. RESULTS: Fifty-two models were included in the synthesis. They demonstrated significant heterogeneity of meaning, form, scope, timing, and purpose. The "lifecycle" may represent a single stage, a series of stages, a cycle of innovation, or a system. "Lifecycle evaluation" focuses on the overarching goal of the stakeholder group, and may use a single or repeated evaluation to inform decision-making regarding the adoption of health technologies (Healthcare), resource allocation (Policymaking), investment in new product development or marketing (Trade and Industry), or market regulation (Regulation). The adoption of a lifecycle approach by regulators has resulted in the deferral of evidence generation to the post-market phase. CONCLUSIONS: Using a "lifecycle evaluation" approach to inform reimbursement decision-making must not be allowed to further jeopardize evidence generation and patient safety by accepting inadequate evidence of safety and effectiveness for reimbursement decisions.


Assuntos
Equipamentos e Provisões , Formulação de Políticas , Equipamentos e Provisões/normas
3.
Proc Inst Mech Eng H ; 237(11): 1243-1247, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37840272

RESUMO

The increase in regulatory challenges on medical technology developed and deployed in the UK is having a negative impact on innovation. In this paper we show how the limited capacity of Approved and Notified Bodies is one more barrier in the innovation pipeline, that could push more teams to consider applying for FDA approval instead of UKCA marking, potentially limiting how much our patients benefit from the world-leading research undertaken in UK universities.


Assuntos
Equipamentos e Provisões , Legislação de Dispositivos Médicos , Reino Unido , Equipamentos e Provisões/normas , Invenções
5.
BMC Health Serv Res ; 23(1): 593, 2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37291513

RESUMO

BACKGROUND: Implementation and uptake of health technology assessment for evaluating medical devices require including aspects that different stakeholders consider relevant, beyond cost and effectiveness. However, the involvement of stakeholders in sharing their views still needs to be improved. OBJECTIVE: This article explores the relevance of distinct value aspects for evaluating different types of medical devices according to stakeholders' views. METHODS: Thirty-four value aspects collected through literature review and expert validation were the input for a 2-round Web-Delphi process. In the Web-Delphi, a panel of participants from five stakeholders' groups (healthcare professionals, buyers and policymakers, academics, industry, and patients and citizens) judged the relevance of each aspect, by assigning a relevance-level ('Critical', 'Fundamental', 'Complementary', or 'Irrelevant'), for two types of medical devices separately: 'Implantable' and 'In vitro tests based on biomarkers'. Opinions were analysed at the panel and group level, and similarities across devices were identified. RESULTS: One hundred thirty-four participants completed the process. No aspects were considered 'Irrelevant', neither for the panel nor for stakeholder groups, in both types of devices. The panel considered effectiveness and safety-related aspects 'Critical' (e.g., 'Adverse events for the patient'), and costs-related aspects 'Fundamental' (e.g., 'Cost of the medical device'). Several additional aspects not included in existing frameworks' literature, e.g., related to environmental impact and devices' usage by the healthcare professional, were deemed as relevant by the panel. A moderate to substantial agreement across and within groups was observed. CONCLUSION: Different stakeholders agree on the relevance of including multiple aspects in medical devices' evaluation. This study produces key information to inform the development of frameworks for valuing medical devices, and to guide evidence collection.


Assuntos
Equipamentos e Provisões , Avaliação da Tecnologia Biomédica , Equipamentos e Provisões/normas , Técnica Delfos , Avaliação da Tecnologia Biomédica/normas
6.
Clin Chem Lab Med ; 61(7): 1150-1157, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-36919280

RESUMO

In May 2022, the European Regulation 2017/746 (IVDR) came into force. It changes the approach of in vitro medical devices (IVD-MDs) for industry and institutions. It reinforces the clinical evidence requirements to improve performance, safety and transparency. Despite extended transition periods and existing guides, IVDR remains difficult to interpret and bringing devices into compliance requires efforts. The generation of clinical evidence is essential to demonstrate compliance with IVDR, and encompasses scientific validity, analytical performance and clinical performance. It is required to demonstrate, per intended use in the target population and clinical care pathway, IVD-MDs clinical performance (compared to a predefined clinical performance). Thus, there is a need for IVD-manufacturers and end-users in health care institutions, to obtain guidance on how to generate this clinical evidence. This article aims industrials and clinicians to identify key steps imposed by the IVDR for bringing IVD-MDs to the EU-market. We propose a general view of performance evaluation requirements for IVD-MDs and provide key references, including how to establish study design that will enable to document clinical performance of existing, refined or emerging medical tests. Finally, we propose a roadmap to address the relevant questions and studies in relation to the documents requested in the IVDR.


Assuntos
Equipamentos e Provisões , Regulamentação Governamental , Equipamentos e Provisões/normas , União Europeia
7.
Med Eng Phys ; 111: 103935, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36792247

RESUMO

The practical use of whole-body vibration training (WBVT) and such research may be negatively influenced by generated vibrations with amplitudes, frequencies, and/or patterns that deviate from preset adjustments on WBVT devices. This study examined whether prolonged regular use can generate respective deviations. Four WBVT devices, used for 19 months in a research project on the effects of WBVT, were analyzed using photogrammetry before start of the research project and after 19 months. Divergences between preset and measured amplitudes and frequencies were calculated for all measurements. To quantify how well the output of devices correlates with the target setting, the vibration characteristics were calculated. In particular, exact long-term measurements related to the vibration amplitude is conducted and analyzed for the first time, which has been found as an important measure of the device functional quality. One device had a significantly (p<0.01) larger machine run time than the other three. This one showed the most pronounced signs of functional impairments concerning instantaneous amplitudes, frequencies and the mode of vibration after prolonged use. These results based on photometric measurements underline again that prolonged use can result in divergences between preset and actual applied amplitudes, frequencies, mode of vibration and other accuracy measurement metrics.


Assuntos
Equipamentos e Provisões , Vibração , Equipamentos e Provisões/normas
8.
Am J Nurs ; 123(3): 21, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36815817

RESUMO

Some needleless Luer-activated valve connectors with internal pins are not compatible with certain prefilled glass syringes. The internal pin can block the glass syringe tip and prevent drug administration.Nurses should be aware of this risk and assist in evaluating the Luer-activated valve connectors used in their organization.


Assuntos
Equipamentos e Provisões , Seringas , Seringas/normas , Equipamentos e Provisões/normas
9.
Comput Intell Neurosci ; 2022: 7324121, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36093491

RESUMO

Equipment health state assessment is of great significance to improve the efficiency of industrial equipment maintenance support and realize accurate support. Using the method driven by the fusion of digital twin model and intelligent algorithm can make the equipment health state assessment more suitable for the "accuracy" requirement of equipment support. Taking the neural network algorithm as an example, this paper studies the method of unit level health state assessment of equipment driven by the fusion of digital twin model and intelligent algorithm. The principle and opportunity of equipment health state assessment based on digital twin model are analyzed, the equipment health state grade is redefined from the data-driven perspective, the selection principles of assessment parameters are established, and the unit level health state assessment model of equipment based on digital twin model and neural network algorithm is established. The proposed method is implemented by programming with Python, and the effectiveness of the method is verified by a case study. It provides support for further research of equipment-level health state assessment and the decision-making of equipment maintenance and provides reference for the study of the combination of digital twin model and other intelligent algorithms for health state assessment.


Assuntos
Algoritmos , Equipamentos e Provisões/normas , Redes Neurais de Computação , Indústrias
10.
Stud Health Technol Inform ; 295: 345-349, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35773880

RESUMO

There is a need to determine the relative similarity and differences in safety issues across specific types of software and medical devices in order to develop standardized solutions that can be used across these technologies. Over the past several years, health informatics researchers have identified differing types of technology-induced errors or safety issues. This work has led to a literature that has been effective in identifying varying technology-induced errors. Less effort has been made in attempting to understand if there are common types of safety issues and outcomes across vendors for specific types of technology such as electronic health records (EHRs). Our findings demonstrate that some safety issues are common across the same type of software. The findings suggest there is a need to develop standardized approaches to managing technology-induced errors.


Assuntos
Tecnologia Biomédica/normas , Equipamentos e Provisões/normas , Informática Médica , Segurança do Paciente , Comércio , Registros Eletrônicos de Saúde/normas
11.
Sensors (Basel) ; 22(6)2022 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-35336377

RESUMO

In the era of the "Industry 4.0" revolution, self-adjusting and unmanned machining systems have gained considerable interest in high-value manufacturing industries to cope with the growing demand for high productivity, standardized part quality, and reduced cost. Tool condition monitoring (TCM) systems pave the way for automated machining through monitoring the state of the cutting tool, including the occurrences of wear, cracks, chipping, and breakage, with the aim of improving the efficiency and economics of the machining process. This article reviews the state-of-the-art TCM system components, namely, means of sensing, data acquisition, signal conditioning and processing, and monitoring models, found in the recent open literature. Special attention is given to analyzing the advantages and limitations of current practices in developing wireless tool-embedded sensor nodes, which enable seamless implementation and Industrial Internet of Things (IIOT) readiness of TCM systems. Additionally, a comprehensive review of the selection of dimensionality reduction techniques is provided due to the lack of clear recommendations and shortcomings of various techniques developed in the literature. Recent attempts for TCM systems' generalization and enhancement are discussed, along with recommendations for possible future research avenues to improve TCM systems accuracy, reliability, functionality, and integration.


Assuntos
Equipamentos e Provisões , Equipamentos e Provisões/normas
15.
JAMA Intern Med ; 182(1): 59-65, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34842892

RESUMO

Importance: Strengthening premarket and postmarket surveillance of medical devices has long been an area of focus for health policy makers. The recent class I recall (the most serious of the US Food and Drug Administration [FDA] recalls) of reperfusion catheters manufactured by Penumbra, a US-based medical device company, illustrates issues of device safety and oversight that mandate attention. Objectives: To review the regulatory history and clinical evidence of the Penumbra JET 7 Reperfusion Catheter with Xtra Flex Technology (JET 7) and use the device recall as a case study of the challenges associated with clinical evaluation, transparency, and oversight of medical devices in the US. Evidence: Regulatory history and clinical evidence for the Penumbra medical devices were analyzed through a qualitative review of decision letters in the Access FDA database for medical devices and medical device reports in the Manufacturer and User Facility Device Experience database and a review of market data (eg, earnings calls, company communications) and clinical literature. Findings: The JET 7 device was subjected to a class I recall following more than 200 adverse event reports, 14 of which involved patient deaths. Regulatory analysis indicated that each of the Penumbra reperfusion catheters was cleared under the 510(k) pathway (which allows devices to be authorized with limited to no clinical evidence), with limited submission of either new clinical or animal data. Clinical evidence for Penumbra devices was generated from nonrandomized, single-arm trials with small sample sizes. The regulatory issues raised by JET 7 are reflective of broader challenges for medical device regulation. Opportunities for reform include strengthening premarket evidence requirements, requiring safety reporting with unique device identifiers, and mandating active methods of postmarket surveillance. Conclusions and Relevance: The case study of JET 7 highlights the long-standing gaps in medical device oversight and renews the impetus to build on the Institute of Medicine recommendations and reform FDA medical device regulation to protect public health.


Assuntos
Aprovação de Equipamentos/normas , Segurança de Equipamentos/normas , Equipamentos e Provisões/normas , Vigilância de Produtos Comercializados/normas , Humanos , Fatores de Risco , Estados Unidos , United States Food and Drug Administration
16.
J Neurosurg ; 136(1): 282-286, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34087794

RESUMO

This article describes the efforts of the US Food and Drug Administration (FDA) Office of Neurological and Physical Medicine Devices to facilitate early clinical testing of potentially beneficial neurological devices in the US. Over the past 5 years, the FDA has made significant advances to this aim by developing early feasibility study best practices and encouraging developers and innovators to initiate their clinical studies in the US. The FDA uses several regulatory approaches to help start neurological device clinical studies, such as early engagement with sponsors and developers, in-depth interaction during the FDA review phase of a regulatory submission, and provision of an FDA toolkit that reviewers can apply to the most challenging submissions.


Assuntos
Equipamentos e Provisões/normas , Estudos de Viabilidade , Doenças do Sistema Nervoso/terapia , Ensaios Clínicos como Assunto , Humanos , Estados Unidos , United States Food and Drug Administration
17.
Rev. baiana enferm ; 36: e44028, 2022. graf
Artigo em Inglês | LILACS, BDENF - enfermagem (Brasil) | ID: biblio-1376463

RESUMO

Objective: to identify the care strategies adopted by nursing professionals in the handling of central catheters in children and newborns hospitalized in an Intensive Care Unit. Method: descriptive research, with quantitative approach, of the non-participant systematic observation type, in a tertiary public hospital in Rio de Janeiro. A structured checklist was applied to the professionals who assisted this clientele. The data were submitted to simple descriptive analysis and organized in graphs. Results: 80 observations were obtained, separated into three stages: moments of hand hygiene; manipulation of the deep catheter; equipment and connectors. Conclusion: the nursing team has satisfactory support to items considered essential in the care and prevention of bloodstream infections related to central catheters in children and newborns hospitalized in the Intensive Care Unit.


Objetivo: identificar las estrategias de cuidado adoptadas por los profesionales de enfermería en el manejo de catéteres centrales en niños y recién nacidos hospitalizados en una Unidad de Cuidados Intensivos. Método: investigación descriptiva, con enfoque cuantitativo, del tipo observación sistemática no participante, en un hospital público terciario de Río de Janeiro. Se aplicó una lista de verificación estructurada a los profesionales que asistieron a esta clientela. Los datos fueron sometidos a un análisis descriptivo simple y organizados en gráficos. Resultados: se obtuvieron 80 observaciones, separadas en tres etapas: momentos de higiene de manos; manipulación del catéter profundo; equipos y conectores. Conclusión: el equipo de enfermería cuenta con un apoyo satisfactorio a los ítems considerados esenciales en el cuidado y prevención de infecciones del torrente sanguíneo relacionadas con catéteres centrales en niños y recién nacidos hospitalizados en la Unidad de Cuidados Intensivos.


Objetivo: identificar as estratégias de cuidado adotadas pelos profissionais de enfermagem no manuseio dos cateteres centrais em crianças e recém-nascidos internados em Unidade de Terapia Intensiva. Método: pesquisa descritiva, com abordagem quantitativa, do tipo observação sistemática não participante, em um hospital público terciário do Rio de Janeiro. Foi aplicado um check-list estruturado aos profissionais que assistiram essa clientela. Os dados foram submetidos a análise descritiva simples e organizados em gráficos. Resultados: obteve-se 80 observações, separadas em três etapas: momentos da higienização das mãos; manipulação do cateter profundo; equipos e conectores. Conclusão: a equipe de enfermagem possui uma adesão satisfatória aos itens considerados essenciais no cuidado e na prevenção de infecções da corrente sanguínea relacionados a cateteres centrais em crianças e recém-nascidos internados em Unidade de Terapia Intensiva.


Assuntos
Humanos , Enfermagem Pediátrica , Cateterismo Venoso Central/enfermagem , Unidades de Terapia Intensiva Pediátrica , Unidades de Terapia Intensiva Neonatal , Enfermagem Neonatal , Equipamentos e Provisões/normas , Cuidados de Enfermagem
19.
Am J Nurs ; 121(10): 46-50, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34554984

RESUMO

ABSTRACT: Advances in medical device technology have led to greater connectivity with other devices, networks, and systems, raising concerns about associated security risks. Many clinicians, as well as the patients who rely on these lifesaving devices, are unaware of these risks and how they can be mitigated. This article describes several types of cyberattacks, including medjacking, hacking, and ransomware, and what nurses can do to guard against security threats and educate patients.


Assuntos
Segurança Computacional/tendências , Equipamentos e Provisões/normas , Tecnologia sem Fio/tendências , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Invenções , Papel do Profissional de Enfermagem , Marca-Passo Artificial , Educação de Pacientes como Assunto , Dispositivos Eletrônicos Vestíveis
20.
Adv Skin Wound Care ; 34(9): 1-6, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34415258

RESUMO

OBJECTIVE: To investigate the evolution of pressure-measuring devices used in compression treatment for venous leg ulcers and assess the most practical and effective devices to determine optimal pressure in compression therapy. DATA SOURCES: Relevant information was retrieved from databases including Google Scholar, PubMed, Wiley Online, and ScienceDirect without publication date restrictions. The keywords included venous leg ulcer, compression therapy, pressure measuring device, pressure sensor, and wireless system. STUDY SELECTION: Studies included in the review had to be published in English and discuss or compare pressure-measuring devices/sensors for compression therapy, the development of alternative sensors, and the applications of wireless technologies. Veterinary studies, conference proceedings, and unpublished articles were excluded. Applicable studies and articles were critically evaluated and synthesized. DATA EXTRACTION: After abstract review, 39 studies were identified. During full-text review, study details were collected using a data extraction form and organized into tables. Device attributes, accuracy, price, and limitations were categorized and analyzed. DATA SYNTHESIS: Studies disagree on the effectiveness and user-friendliness of existing pressure-measuring devices. These devices often impact user comfort and convenience, which are crucial factors in the adoption and use of wearable devices. Potential solutions for pressure-measuring devices with promising technologies were proposed: four feasible alternative sensors are described that could improve comfort and facilitate prolonged use under bandages. Advanced communication technologies may provide more convenience for users and practitioners. CONCLUSIONS: Conventional pressure-measuring devices used in compression therapy are not designed for the user's comfort and convenience. The use of flexible and stretchy pressure sensors (e-skin) provides good biocompatibility, conformability, and comfort and when integrated with near-field communication technology could address the drawbacks of current pressure-measuring devices.


Assuntos
Bandagens Compressivas/normas , Úlcera da Perna/terapia , Pesos e Medidas/instrumentação , Bandagens Compressivas/estatística & dados numéricos , Equipamentos e Provisões/normas , Humanos , Pressão/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA